Installation Qualification of QC- Facility Qualification

Installation Qualification of QC- Facility Qualification consists of the installing QC laboratory in the existing and new facility. The Installation Qualification (IQ) phase provides documented verification that all structural elements, environmental control systems, utilities, and analytical equipment for the Quality Control (QC) laboratory have been correctly installed and configured in accordance with the approved Design Qualification (DQ), User Requirements Specifications (URS), and prevailing Good Manufacturing Practice (GMP) standards.

TABLE OF CONTENT

DescriptionPage No.
Title Page 
Table of Contents 
Pre – Approval of Documents 
Objective 
Scope 
Responsibilities 
Facility Installation Operation Brief Description 
Critical Attributes to be met while Installing facility 
Critical Attributes to be met while operating facility 
General observation Checklist for Installation Qualification 
Installation Specifications (Area Wise) 
Summary and Conclusion for IQ 
Post Approval of Installation Qualification 
General observation Checklist for Installation Qualification 
Abbreviations 
Reference 
Post Approval of Document 
Revision History 

Pre-Approval of Documents:

  PREPARED BY:-

NameDesignation/DepartmentSignatureDate
            

  REVIEWED BY:-

NameDesignation/DepartmentSignatureDate
            
      
    

APPROVED BY:-

NameDesignation/DepartmentSignatureDate
            

Objective considered Installation Qualification of QC- Facility Qualification :

This document is generating under the authority of the XYZ company for the purpose of specifying the Installation Operation Qualification for new Quality Control Lab. To establish documented evidence that the Quality Control (QC) area infrastructure, utilities, and environmental conditions are installed correctly Installation Qualification in compliance with predefined specifications.

Scope:

The scope of this document is to define the requirements for new Quality Control lab.in XYZ Company.

Responsibilities

DepartmentResponsibility
Quality assurancePreparation of Installation Operation Qualification protocol cum report
Execution of Installation Operation Qualification   Review of IOQ
Pre & Post Approval of IOQ
Responsible for the compliance of IOQ
EngineeringReview of IOQ
Support in execution of Installation Operation Qualification
To assist concerned department for the preparation of IOQ
Quality ControlReview of IOQ
To assist concerned department for the preparation & execution of IOQ

Installation Qualification of QC- Facility Qualification Brief Description :

The Quality Control (QC) facility is designed, installed & operated to support analytical testing of raw materials, in-process samples, and finished products in compliance with applicable regulatory requirements.

The installation & Operation includes:

Facility Layout & Segregation:

The QC area is properly segregated into designated sections such as chemical testing laboratory, instrument room, sample receipt & storage area, and documentation area. Layout ensures unidirectional flow of personnel and materials to prevent cross-contamination.

Civil & Structural Components:

Walls, floors, and ceilings are constructed with smooth, cleanable, and non-reactive materials. Adequate drainage and pest control measures are implemented.

Utilities Installation:

Essential utilities including electrical supply, purified water system (if required), and HVAC systems are installed and operated as per design specifications.

Laboratory Equipment & Instruments:

Analytical instruments (e.g., HPLC, UV spectrophotometer, balances) are installed as per manufacturer specifications, properly labeled, and calibrated.

Safety Systems:

Installation of fire extinguishers, eye wash stations, fume hoods, and emergency exits is verified.

Documentation:

Availability of equipment manuals, calibration certificates, SOPs, and layout drawings is ensured.

Critical Attributes to be met while Installation Qualification of QC- Facility Qualification

Facility Design & Layout

  • Adequate segregation of different functional areas (chemical, instrumental)
  • Logical workflow to avoid cross-contamination and mix-ups
  • Sufficient space for equipment operation and maintenance

Construction & Finishes

  • Smooth, non-shedding, and easily cleanable surfaces (walls, floors, ceilings)
  • Chemical-resistant work surfaces
  • Proper drainage and pest control provisions

Utilities

  • Reliable electrical supply with proper earthing
  • Adequate number of power points for instruments
  • Availability of required utilities:
  • HVAC system
  • Purified water system (if required)

HVAC & Environmental Control

  • Proper installation of HVAC system
  • Defined temperature and humidity control
  • Adequate ventilation

Safety Systems

  • Installation of fire extinguishers
  • Availability of eye wash stations with safety showers
  • Proper installation of fume hoods and exhaust systems

Documentation

  • Approved layout drawings
  • SOPs for operation and maintenance
  • Equipment manuals and qualification documents

General Observation Checklist for Installation Qualification of QC- Facility Qualification

ObjectiveObservation
Area Cleanliness 
Completion of Design Qualification 

Installation Specifications (Area Wise)

Section usually lists the Installation Operation requirements and specifications for each functional area of the facility, system, or equipment. This helps verify that the Installation Operation meets regulatory, Design Qualification (DQ) and GMP requirements.

Change Room, Instrumentation room, Chemical Lab, Sample Storage area, Balance room, Chemical storage required Installation Qualification of QC- Facility Qualification

CHECK POINTS                   REQUIREMENT
Description 
Check the dimension of the room  (length, width, and height in meters / metric system).Should be adequate as per drawing
Access controlAccess control should be installed
Identification
Area Finish
Area Epoxy work               Should be Neat and clean
Panel Surface finishSuitable paint depending on wall type (if any)
Panel to panel joints/gaps with Silicon work finishPP strips coving available
Panel to panel coving with PP strips                   Coving should be available
PP strips coving with silicon work finishThere should be no gaps remaining
Wall to floor coving with sand covingCoving surface should be smooth
Sand coving surface finish should be smoothCoving surface should be smooth
Floors of Area
Ensure floor to wall corners have smooth coved surfaces.Coving surface should be smooth
Ensure slope has easy flow of water towards drain where ever it is required.Slope should be towards the drain point
Ensure that floor surface in the area is easy to clean.Floor surface should be easy to clean
Ceiling of Area & Air lock:
Verify the appropriate ceiling of the area.No gaps should be found
Ceiling to panel/wall coving with PP stripsCoving should be smooth and cleaned
Doors of Area & Air lock:
Numbers of door as per area.
Check that proper direction stickers are provided in all door i.e, (Push and Pull).
Door view glass availability finished with silicon workThere should be no gap b/w view glass and door
Number of Door Closer
Number of Door SS handle
Door electric magnet (if interlocking in place) is installed
Direction of doorOpens towards positive or pressure
Door Base air seal (Drop Seal) 
Door Interlocking Switches 
Panel/View Panel/window of Area
Ensure that it is properly sealed to prevent dirt accumulation.Flush with wall panels to avoid dust accumulation
Check the material of construction, as per design.Pre-coated panels with PUF (Polyurethane Foam) insulation Double-glazed toughened glass
Check single/double glass, colour of glass, type of glass as per requirement.Double-glazed toughened glass Flush fitted with panel system
No. of view panel
View panel glass should be present with silicon work finishThere should be no gap b/w window glass and panel/wall
Electrical Works:
Wiring of Area:
Electric switches at respective location
Verify all the electrical cables present in the room are concealed.Electrical switches should be concealed
Lighting of Area
Number of LED/Monochromatic lights of area as per drawing
Location of the connections and its voltage and phase.Connections should be concealed
Size of LED/Monochromatic lights as per drawing
Openable from area side by screw or from service floor
No. of electrical switches/sockets Electrical of switches should be concealed
Air Handling System of Area
Check the number of Supply grills in area
Check the number of Return grills in area
Supply grills are fixed (Screw/magnet)
Return grills are fixed (Screw/magnet)
Services/Utilities:
Machine Utility Supply Line AvailabilityRequired and supply line should be concealed
Compressed Air line availability
Power plugs and socketsShould be concealed
Process water supply line
Purified water supply loop (if applicable)Purified water line should be available and marked
Drains:
Check number of drain points.Should be GMP drains
Check the slope for water draining.Slope should be towards the drain
Check the wash basin/sink
General Requirement :
Man movement and Material Flow:
Availability of entry and exit for man and material flow.
Pass Box
Check number of pass box and its type static or dynamic as per requirement.(If applicable)

Summary and conclusion for Installation Qualification

__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

Post Approval of Installation Qualification

CHECKED BY:-

NameDesignation/DepartmentSignatureDate
            

REVIEWED BY:-

NameDesignation/DepartmentSignatureDate
            
      
    

APPROVED BY:-

NameDesignation/DepartmentSignatureDate
            

FAQ’s for for Installation Qualification of QC- Facility Qualification

Q: What is a QC Lab IQ?

Answer: It is the documented proof that all lab structures, utilities, HVAC systems, and instruments are installed correctly and meet GMP standards.

Q: How does IQ differ for a new vs existing facility?

Answer: A new facility focuses on fresh utility, HVAC and cleanroom while an existing facility focuses on safe integration.

Q: What are the main things checked during IQ?

Answer: Floor epoxy, coving, Panels, doors, HVAC systems, HEPA filters, grills, pressure gauges, utilities like purified water, and proper instrument placement.

Q: What happens if anything fails during IQ ?

Answer: If anything shall be failed then deviation shall be raised and the issue shall be corrected and re-verified before proceed to further stage.